Hot Runner Systems for the Plastics Processing Industry
|
The Hot Runner System also features LED's for under temperature or over temperature indication, Heat load on/off, Ramp start, and Open or closed loop operation. The display can also be set for set point or process temperature indication and a +/- 3 degree indicator flashes when process temperature is within 3 degrees of setpoint. Hot Runner System control modules are also designed for full communication capability with alarm and standby module. Hot Runner System Features: • Microprocessor based controllers • Automatic tuning PID Control
• Touch pad front panel controls • Soft start ramp up standard feature • Auto or manual mode available thermocouple status indicator • Current indication setpoint or process indication • Under/over temperature indication Hot Runner System Specifications: Voltage. . . . . . . . . . . . . . .120 or 240 voltsOutput Current/ Watts. . . . .15 amps 3600 watts at 240 1800 at 120 Input. . . . . . . . . . . . . . . . Type J thermocouple Grounded or ungrounded T/C Break protection. . . . . . Inhibits power to heater Control Accuracy. . . . . . . . +/-1ºF or +/- .5ºC Temperature Range. . . . . . .Ambient to 999ºF (535ºC) Cycle time. . . . . . . . . . . . .0.33 seconds Manual control. . . . . . . . . .Adjustable from 0 to 100% Ramp Start. . . . . . . . . . . . Duration 5 minutes Output. . . . . . . . . . . . . . . Zero cross triac triggering Data Communication. . . . . . IBM PC compatible Compatibility. . . . . . . . . . . Hot runner industrial standard compatible Accessories. . . . . . . 600 to 240 volts step down transformers Power connectors 5, 8,12, zones Thermocouple connectors 5, 8,12 zones Floor Stands will support up to 48 zones Main Frames 5, 8,12, Stackable to 48 zones |